Select your language


Key data:

  • Measuring / purge and continuous output stage to control one HDEV6 injector
  • Parameterization via serial LVDS high-speed interface (via HDEV6 controller PN2350)
  • Up to 5 multiple injections and max. 4 multiboosterings possible
  • Current values switch controlled
  • Adjustable number of triggers (pulse preselection)
  • Definition of monitoring / shutdown criteria
  • Display of last current and voltage profile via VSGControl2 software
    • Detection of injector faults:
    • Interruption
    • Short circuit
    • Ground fault
    • Winding fault
  • Detection of hardware defects
    • Fuse defective
    • Sense lines interrupted
  • Overtemperature protected power stage

 

Further information can be found in the manual of the module
(Download only possible after user registration).


Key data:

  • Measuring output stage for driving up to 2 high-impedance injectors (10...20Ohm)
  • Two independently controllable output stages
  • Trigger pulse can be configured separately for each output stage by means of a jumper. Thus control with LOW or HIGH active trigger pulse possible.
  • Lengthening or shortening of the trigger pulse adjustable
  • Current monitoring can be deactivated via jumper
  • Suitable for UBmin measurements
  • Control of injector according to circuit no. 1 289 917 057 of Robert-Bosch GmbH (PN2088 | PMH)
  • Control of the injector according to circuit no. 1 289 917 094 of Robert-Bosch GmbH (PN2088-01 | CH1)
  • Control of the injector according to circuit no. 1 289 917 156 of Robert-Bosch GmbH (PN2088-02 | MB1)

 

Further information can be found in the manual of the module
(Download only possible after user registration).

 


Key data:

  • Measuring output stage for driving up to 2 high-impedance injectors (10...20Ohm)
  • Two independently controllable output stages
  • Trigger pulse can be configured separately for each output stage by means of a jumper. Thus control with LOW or HIGH active trigger pulse possible
  • Lengthening or shortening of the trigger pulse adjustable
  • Current monitoring can be deactivated via jumper
  • Suitable for UBmin measurements
  • Control of injector according to circuit no. 1 289 918 753 of Robert-Bosch GmbH (PN2208 | LE)
  • Control of the injector according to circuit no. 1 289 918 756 of Robert-Bosch GmbH (PN2208-01 | DE1)
  • Control of the injector according to circuit no. 1 289 917 716 of Robert-Bosch GmbH (PN2208-02 | FE1)

 

Further information can be found in the manual of the module
(Download only possible after user registration).

 


Eckdaten:

  • Measuring output stage for driving up to 2 high-impedance injectors (10...20Ohm)
  • Two independently controllable output stages
  • Trigger pulse can be configured separately for each output stage by means of a jumper. Thus control with LOW or HIGH active trigger pulse possible.
  • Lengthening or shortening of the trigger pulse adjustable
  • Current monitoring can be deactivated via jumper
  • Suitable for UBmin measurements
  • Control of the injector according to circuit no. 1 289 918 801 of Robert-Bosch GmbH

 

Further information can be found in the manual of the module
(Download only possible after user registration).